Ainfo Consulta

Catálogo de Información Agropecuaria

Bibliotecas INIA

 

Botón Actualizar


Botón Actualizar

Acceso al texto completo restringido a Biblioteca INIA La Estanzuela. Por información adicional contacte bib_le@inia.org.uy.
Registro completo
Biblioteca (s) :  INIA La Estanzuela.
Fecha :  16/03/2022
Actualizado :  16/03/2022
Tipo de producción científica :  Artículos en Revistas Indexadas Internacionales
Autor :  REGUEIRO, M.; JORGE-SMEDING, E.; SARAVIA, A.; LÓPEZ-MAZZ, C.; BANCHERO, G.
Afiliación :  MARIEL REGUEIRO, Department of Animal Production and Pastures, Faculty of Agronomy, UDELAR, Av. Garzon 780, Montevideo 12900, Uruguay.; EZEQUIEL JORGE-SMEDING, Department of Animal Production and Pastures, Faculty of Agronomy, UDELAR, Av. Garzón 780, Montevideo 12900, Uruguay; ANDERSON SARAVIA DE MELO, INIA (Instituto Nacional de Investigación Agropecuaria), Uruguay; CARLOS LÓPEZ-MAZZ, Department of Animal Production and Pastures, Faculty of Agronomy, UDELAR, Av. Garzon 780, Montevideo 12900, Uruguay.; GEORGGET ELIZABETH BANCHERO HUNZIKER, INIA (Instituto Nacional de Investigación Agropecuaria), Uruguay.
Título :  Comparison between pulse oximetry and venous blood gas analyses to assess lamb asphyxia at parturition.
Fecha de publicación :  2022
Fuente / Imprenta :  Small Ruminant Research, 2022, Volume 21, Article number 106665. doi: https://doi.org/10.1016/j.smallrumres.2022.106665
DOI :  10.1016/j.smallrumres.2022.106665
Idioma :  Inglés
Notas :  Article history: Received 28 June 2021; Received in revised form 2 March 2022; Accepted 3 March 2022; Available online 4 March 2022.
Contenido :  ABSTRACT: Early detection of fetal distress at lambing is essential to reduce mortality. Practicality and accuracy of pulse oximetry to assess oxygenation status in newborn lambs under field conditions was evaluated. Oximetry was compared with blood gas analyses and included assessment of vitality (Apgar test) and vigour (attempt to and successful standing and suckling) of 135 Finnish by Polwarth lambs. Sampling of data was obtained immediately after fetal expulsion; percentage of oxygen saturation (satO2) was measured using a pulse oximeter clamped to an ear, and was compared with gas analyses variables measured from a jugular vein sample (Gas Analyser: SiemensRapidlab 248®). Correlations between satO2 measured by pulse oximetry and venous blood gas parameters either directly (partial pressure of carbon dioxide (pCO2), partial pressure of oxygen (pO2) and pH) or estimated (bicarbonate concentration, extracellular fluid base excess, and oxygen saturation) were studied. Considering pH as a good indicator of hypoxia at parturition, data was grouped as: G1 = pH < 7.1; G2 = 7.1 ? pH < 7.2; G3 = 7.2 ? pH < 7.3 and G4 = pH ? 7.3. Saturation of oxygen measured by pulse oximetry correlated significantly with pCO2 (r = ? 0.50; P < 0.001), pH (r = 0.36; P < 0.001) and pO2 (r = 0.2, P = 0.04) measured by blood gas analyses. Lambs with low pH values (G1 = pH ? 7.1, acidosis) showed the lowest percentage to attempt and success to stand and suck, lowest Apgar score (G1 = 6.7, G2 = 8.6, ... Presentar Todo
Palabras claves :  Blood gas analysis; Labour phase II; Lamb asphyxia; Ovine; Pulse oximetry.
Thesagro :  OVINOS.
Asunto categoría :  --
Marc :  Presentar Marc Completo
Registro original :  INIA La Estanzuela (LE)
Biblioteca Identificación Origen Tipo / Formato Clasificación Cutter Registro Volumen Estado
LE103500 - 1PXIAP - DDPP/Small Ruminant Research/2022

Volver

Expresión de búsqueda válido. Check!
Expresión de búsqueda válido. Check!
 
 

Embrapa
Todos los derechos reservados, conforme Ley n° 9.610
Política de Privacidad
Área Restricta

Instituto Nacional de Investigación Agropecuaria
Andes 1365 - piso 12 CP 11100 Montevideo, Uruguay
Tel: +598 2902 0550 Fax: +598 2902 3666
bibliotecas@inia.org.uy

Valid HTML 4.01 Transitional